Galileo Equipments

CG-MS Varian CP3800 Saturn 2200

GC-MS system consisting Varian Sarturn 3800 gas chromatograph with MS and ion trap mass spectrometer Varian 2200. The control software allows easy operation of different configurations. This unit is perfect. Includes Manuals, Software, PC, monitor and printer.

More details


26 235,00 €

GM007

Realice su pedido por teléfono (+34 91 192 37 37 ) o por e-mail (info@galileoequipos.com)
Place your order by phone (+34 91 192 37 37) by e-mail (info@galileoequipos.com)


 

2200 MS Specifications

Mass range: 10 to 650 u; scan range is time programmable throughout the run
Selected Ion Storage (SIS): stores up to five ranges of ions or five ions (u-SIS mode); ejects up to five ions, e.g., column bleed
Scan rate: fixed at 5600 u/sec to maximize spectral acquisition
Resolution: unit mass, measured as 10% valley, over the entire range
Mass calibration stability: RF-only field is stable for weeks to several months at constant analyzer temperature and helium flow
Linear dynamic range: 103 to 104 (compound dependent based upon
analytical methods)
Filament assembly: dual filament
Transfer line temperature: independent control; maximum 350 °C
Manifold temperature: independent control; maximum 120 °C
Analyzer temperature: independent control; anodized block; maximum 250 °C
Electrode surface: chrome (standard)
Ion gauge: Bayard-Alpert gauge tube with burn-out resistant, thoria-coated iridium (ThO-Ir) filaments
Power fail protection: solenoid closes septum purge line and supplies supplemental helium flow through the column to vent MS
Turbomolecular pump: Varian V-70 pump, air cooled, and thermostatically
protected; 70 L/s capacity; pumping at 60 L/s supplies a vacuum of approximately 10-5 Torr (1.3 mPa) in the manifold

Power Requirements
100-130 Vac, 60 Hz ± 3 Hz, 12 Amps, 1.5 kilowatt
200-260 Vac, 50 Hz ± 3 Hz, 6 Amps, 1.5 kilowatt

Environmental Requirements
Humidity: 20% to 80% relative humidity (without condensation)
Temperature: 15 °C to 30 °C

3800 GC Specifications

Column Oven
Size: 11 in./28 cm (h) x 11 in./28 cm (w) x 7.5 in./19 cm (d)
Temperature range: ambient +4 °C to 450 °C; -99 °C to 450 °C with liquid N2; -65 °C to 450 °C with liquid CO2
Temperature-programmed ramps: 7 ramps with 8 isothermal holds
Maximum temperature ramp rate: 100 °C/min for all voltages
Cool-down rate: 400 °C to 50 °C in 4.5 min

Injectors
CP-1177 Split/Splitless Injector
Temperature range: 50 °C to 450 °C isothermal
1079 PTV Injector
Temperature range: -99 °C to 450 °C with liquid N2; -65 °C to 450 °C with liquid CO2
Maximum temperature ramp rate: 200 °C/min
Temperature ramps: 4 Injector EFC
Pressure range: 0-100 psi
Total flow: 500 mL/min at 10 psi

Power Requirements
120 Vac ± 10%, 60 Hz ± 2%, 20 Amps, 2.4 kilowatt
230 Vac ± 10%, 50 Hz ± 2%, 10 Amps, 2.3 kilowatt
101 Vac ± 10%, 50 or 60 Hz ± 2%, 25 Amps, 2.5 kilowatt

Environmental Requirements
Humidity: 5% to 95% relative humidity (without condensation)
Temperature: 10 °C to 40 °C operating

DS102 Foreline Pump
Dual stage, rotary vane
Voltage: 120/230V switchable
Pumping speed greater than 95 L/min (5.7 m3/hr)
Dimensions: 8.3 in./21 cm (h) x 5.2 in./13 cm (w) x 16.9 in./43 cm (d)
Weight: 48 lb/22kg

CG-MS Varian CP3800 Saturn 2200

Manufacturer

Model

Mass detector

Varian

Saturn 2200

Gas Chromatograph

Varian

CP 3800

CPU

Dell

optiplex 745

Monitor, software & manuals

DELL

1097 FTp

Printer

Hp

LaserJet1022

Vacuum pump



 

Cart  