Varian SPECTR AA 50B Maximize

Varian SPECTR AA 50B

Varian AA SPECTR 50B Flame AA Spectrophotometer. With: 2 burners (air acetylene and acetylene nitrous oxide), 14 lamps (As, Se, B, Sb, V, Co / Cr / Cu / Fe, Mn / Ni, Sr, Li, Ag / Cd / Pb / Zn, Ba, Mo, Hg, Ca / Mg / Al, Na / K), manometer for acetylene bottle, manometer for bottle of nitrous oxide with heating mantle, air compressor (Jun-Air), stainless steel hood. Delivery time1 month.

More details

SP037

7 850,00 € tax excl.

Specifications:

MODEL

SpectrAA 50

BURNER-ATOMIZER Changeable, laminar, adjustable, optional N2O, premix universal atomizer with fully adjustable nebulizer, fully shielded flame with double-skin chimney
OTHER INFORMATION (STAINING POSTS) Can be linked to a PC, but not required for operation; optional Windows software; multitasking; multielement; software choice of 11 QC tests or full EPA and user-definable tests; optional software to assist with compliance with FDA 21 CFR Part 11; range o
FORMAT (WAVELENGTH, nm) 1 channel, single beam - for more information please see comments.1 channel, single beam, time-shared
MONOCHROMATOR Czerny-Turner with 1,200 lines/mm, holographic quartzovercoated grating, automatic wavelength & slit-size control
Focal length, mm (DIMENSIONS (HXWXD), MAIN) 250
WAVELENGTH RANGE, nm (UV RADIATION INTENSITY) 185-900
RESOLUTION, nm 0.2, 0.5, 1; 0.5 reduced
BACKGROUND CORRECT (DETECTION LIMITS,ppb) Optional, fast (2 msec) deuterium arc lamp to 2.3 absorbance units, 185-425 nm, electronic beam balance 2
GAS REGULATORS Manual control with automatic gas changeover; interlocks on power, gas, burner present, burner type, flame, spray-chamber bung, flame shield, liquid trap; cutoff solenoids external to instrument case With automatic attenuation.
Ignition Push button, automatic flame off
DISPLAYED INFORMATION (DETECTION LIMITS,ppb) Built-in LCD screenemission, absorption, concentration, direct absorbance, calibration graph, several languages
Working curve (DETECTION LIMITS,ppb) Blank and 5 standards, 1 algorithm
Memory 30 custom methods plus cookbook methods for each element, full export to LIS, printer 4
Integration, sec (DETECTION LIMITS,ppb) 0.2-60 (1-10 replicates), integrate repeat, PrOMT system 6 Also SIPS-10 support.
Graphics (DETECTION LIMITS,ppb) Monochrome PrOMT is a feature that allows the user to specify the precision required; the instrument measures the sample for the time required to achieve thatprecision.
PRINTER (EXTERNAL BEAM) Optional serial printer
Microcomputer (DETECTION LIMITS,ppb) Built-in Or use serial to parallel converter with parallelprinter.
INTERFACE PROTOCOL (REPORT DISPLAY) Optional, PCI-IEEE
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY) 59 x 79 x 58 (23.2 x 31 x 23)
WEIGHT, kg (lb) (DISPLAY) 56 (123)
POWER NEEDED 220/230/240
Hz (OPERATING) 50/60

  • Height 59 cm
  • Width 79 cm
  • Depth 58 cm
  • Weight 56 kg

No customer comments for the moment.

Write your review

Varian SPECTR AA 50B

Varian SPECTR AA 50B

Varian AA SPECTR 50B Flame AA Spectrophotometer. With: 2 burners (air acetylene and acetylene nitrous oxide), 14 lamps (As, Se, B, Sb, V, Co / Cr / Cu / Fe, Mn / Ni, Sr, Li, Ag / Cd / Pb / Zn, Ba, Mo, Hg, Ca / Mg / Al, Na / K), manometer for acetylene bottle, manometer for bottle of nitrous oxide with heating mantle, air compressor (Jun-Air), stainless steel hood. Delivery time1 month.

Write your review