Varian SPECTR AA 50B

Espectrofotómetro de AA de llama Varian SPECTR AA 50B.  Incluye: 2 mecheros (Aire acetileno y Acetileno Oxido nitroso), 14 lámparas (As, Se, B, Sb, V, Co/Cr/Cu/Fe, Mn/Ni, Sr, Li, Ag/Cd/Pb/Zn, Ba, Mo, Hg, Ca/Mg/Al, Na/K), manómetro para botella acetileno, manómetro para botella de oxido nitroso con manta calefactora, compresor de aire (Jun-Air), campana de acero inoxidable. Plazo entrega 1 mes.

Más detalles

SP037

7 850,00 € sin IVA

Especificaciones:

MODEL

SpectrAA 50

BURNER-ATOMIZER Changeable, laminar, adjustable, optional N2O, premix universal atomizer with fully adjustable nebulizer, fully shielded flame with double-skin chimney
OTHER INFORMATION (STAINING POSTS) Can be linked to a PC, but not required for operation; optional Windows software; multitasking; multielement; software choice of 11 QC tests or full EPA and user-definable tests; optional software to assist with compliance with FDA 21 CFR Part 11; range o
FORMAT (WAVELENGTH, nm) 1 channel, single beam - for more information please see comments.1 channel, single beam, time-shared
MONOCHROMATOR Czerny-Turner with 1,200 lines/mm, holographic quartzovercoated grating, automatic wavelength & slit-size control
Focal length, mm (DIMENSIONS (HXWXD), MAIN) 250
WAVELENGTH RANGE, nm (UV RADIATION INTENSITY) 185-900
RESOLUTION, nm 0.2, 0.5, 1; 0.5 reduced
BACKGROUND CORRECT (DETECTION LIMITS,ppb) Optional, fast (2 msec) deuterium arc lamp to 2.3 absorbance units, 185-425 nm, electronic beam balance 2
GAS REGULATORS Manual control with automatic gas changeover; interlocks on power, gas, burner present, burner type, flame, spray-chamber bung, flame shield, liquid trap; cutoff solenoids external to instrument case With automatic attenuation.
Ignition Push button, automatic flame off
DISPLAYED INFORMATION (DETECTION LIMITS,ppb) Built-in LCD screenemission, absorption, concentration, direct absorbance, calibration graph, several languages
Working curve (DETECTION LIMITS,ppb) Blank and 5 standards, 1 algorithm
Memory 30 custom methods plus cookbook methods for each element, full export to LIS, printer 4
Integration, sec (DETECTION LIMITS,ppb) 0.2-60 (1-10 replicates), integrate repeat, PrOMT system 6 Also SIPS-10 support.
Graphics (DETECTION LIMITS,ppb) Monochrome PrOMT is a feature that allows the user to specify the precision required; the instrument measures the sample for the time required to achieve thatprecision.
PRINTER (EXTERNAL BEAM) Optional serial printer
Microcomputer (DETECTION LIMITS,ppb) Built-in Or use serial to parallel converter with parallelprinter.
INTERFACE PROTOCOL (REPORT DISPLAY) Optional, PCI-IEEE
DIMENSIONS (HXWXD) CM, (IN) (DISPLAY) 59 x 79 x 58 (23.2 x 31 x 23)
WEIGHT, kg (lb) (DISPLAY) 56 (123)
POWER NEEDED 220/230/240
Hz (OPERATING) 50/60


  • Alto 59 cm
  • Ancho 79 cm
  • Profundo 58 cm
  • Peso 56 kg

No hay comentarios de clientes por ahora.

Escribe tu opinión

Varian SPECTR AA 50B

Varian SPECTR AA 50B

Espectrofotómetro de AA de llama Varian SPECTR AA 50B.  Incluye: 2 mecheros (Aire acetileno y Acetileno Oxido nitroso), 14 lámparas (As, Se, B, Sb, V, Co/Cr/Cu/Fe, Mn/Ni, Sr, Li, Ag/Cd/Pb/Zn, Ba, Mo, Hg, Ca/Mg/Al, Na/K), manómetro para botella acetileno, manómetro para botella de oxido nitroso con manta calefactora, compresor de aire (Jun-Air), campana de acero inoxidable. Plazo entrega 1 mes.

Escribe tu opinión