BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
  • BD Biosciences FACSCanto
CI011
Equipment second hand | Cytometry | BD Biosciences FACSCanto
0 Item
BD Biosciences FACSCanto
Bekton Dickinson
27.500,00 €
Taxes excluded
Icon
1 año garantía

1 year warranty

Flow cytometer Beckton Dickinson FacsCanto. It consists of 7 light sensors, PMT, Laser Blue 488 nm and Red Laser 633 nm. Preamps for each PMT. Parameters: (FSC) (SSC), and 6 fluorescence: FL1, FL2, FL3, FL4, FL5 and FL6. Module fluids: BD Facts Shut down, Facs Clean, Sheat Fluid and waste. Software FACs Diva, 2 screens and a computer tower. Includes manuals.

Installation
Qty

Specifications:

  • Equipped with a blue laser, solid state (488), red laser he-Ne (633 nm).
  • Allows you to work with eight fluorescence and two-parameter scatter (FSC and SSC), analyzing for each one of them to the area, height and width of the pulse.
  • Processing system digital signal with the software FACSDiva. This program allows the compensation off-line and the configuration of scales biexponenciales.
 
  • 110/115/230V
  • 50-60Hz
  • 50W
 
  • Lasers
    • Air-cooled:
    • 488-nm solid state, 20-mW laser output
    • 633-nm HeNe, 17-mW laser output
  • Configuration of the laser Spot spatially separated with brands elliptical 9 x 65-μm
  • Does not require alignment by the operator.
  • Flow-cell: 180 x 430-µm cell flow cell in a quartz rectangular
  • Collection optics: Optical-gel eparejado with lenses 1.2 NA
  • FSC Resolution: 0 ám
  • SSC Resolution: 5 µm
  • Design of the dectector of fluorescence: Optical reflector with filter of transmission only in front of each PMT.
  • Detector FSC. Fotodiodo with filter of 488/10 BP
  • Detector SSC: PMT filter of 488/10 BP
  • Fluorescence Detector: 6 PMTs in standard configuration 4-2
  • Fluorochromes for blue laser:
    • FITC, PE, PerCP or PerCP-Cy™5.5,
    • PE-Cy7 (525, 575, 678 or 695, 785 nm)
  • Fluorophores for the red laser: APC, APC-Cy7 (660, 785 nm)
  • Strip Detector:
    • Blue laser: 530/30; 585/42; >670; 780/60 nm
    • Red laser: 660/20; 780/60 nm
  • Threshold of sensitivity of fluorescence: FITC <100 MESF; PE <50 MESF